On Fri, 29 Jul 2005, H. Henning Schmidt wrote:
You can configure your serial port -attached file-desc to return after one
single byte or after a timeout by configuring the appropriate members of the
struct termios -member <c_cc>. Read
http://www.easysw.com/~mike/serial/serial.html for details.
;Henning
Thanks Henning! Got it working by adding the following to the settings I
already had:
// ignore modem control lines and enable the receiver
tios.c_cflag |= (CLOCAL|CREAD);
// minimum number of characters before read() returns
tios.c_cc[VMIN] = 6;
Kind regards,
Mike McCarthy
--